Understanding IEC 62366 for Medical Devices: Designing for Usability

by | Jan 8, 2025 | Compliance and Regulatory Guidance, US FDA Regulatory Requirements | 0 comments

Understanding IEC 62366 for Medical Devices

When a nurse or surgeon picks up your medical device, will they intuitively know how to use it—or will they hesitate? IEC 62366 for medical devices helps you design devices that eliminate confusion and prioritize safety.

Usability in medical devices isn’t just a nice-to-have—it’s a must. Devices that are hard to understand or use can lead to mistakes, delays, and even life-threatening consequences. And let’s be real: no one wants their product associated with patient harm or regulatory trouble.

That’s where IEC 62366, the international usability standard for medical devices, comes in. Think of it as your roadmap to designing devices that are intuitive, user-friendly, and compliant with regulatory requirements. Whether it’s a simple orthopedic drill or complex diagnostic equipment, this standard helps you avoid critical use errors and ensure your device performs as intended.

In this post, we’ll break down exactly what IEC 62366 for medical devices is, why usability matters, and how following this standard can make a big difference—not just for patient safety, but also for your bottom line. We’ll walk through the usability engineering process, share tips for implementation, and show how embracing a culture of usability can set you apart.

Ready to create devices that users trust and regulators approve? Let’s dive in.

What is IEC 62366 for Medical Devices, and Why Does It Matter?

If you’ve ever wondered how to make your medical device not just functional but intuitive, IEC 62366 for medical devices is the answer. It’s the international usability standard that ensures medical devices are designed with the user—and patient safety—in mind.

At its core, IEC 62366 for medical devices focuses on minimizing risks caused by use errors—the kind that can happen when a device is too complicated, poorly labeled, or just plain confusing. These errors can lead to everything from minor delays in care to serious harm for patients and users.

The standard doesn’t just stop at the design itself—it guides manufacturers through the entire development process. It helps you identify potential usability risks early on, integrate solutions into the design, and verify that your device is safe and easy to use in real-world scenarios.

Over the years, IEC 62366 has evolved. Today, it’s split into two parts:

  • IEC 62366-1: The main usability engineering process, which is mandatory for compliance.
  • IEC TR 62366-2: A companion guide that provides examples and practical tips to help manufacturers implement the standard effectively.

So, why does this matter? Because usability isn’t just about making a device nice to use—it’s about making it safe to use. Following IEC 62366 ensures your device meets global regulatory requirements, reduces risks, and builds trust with your users.

Why Usability Matters in Medical Devices

Imagine a surgeon struggling to navigate the controls of a life-saving device in the middle of a critical procedure. Or a patient at home confused about operating their insulin pump. Poor usability in medical devices isn’t just frustrating—it can have serious, even fatal, consequences.

When devices are hard to use, mistakes happen. These mistakes—called use errors—are often tied to design flaws rather than user incompetence. A button that’s too small, unclear instructions, or an overly complicated interface can all lead to dangerous situations.

Take this real-world example: A poorly designed infusion pump led to a dosing error, causing harm to patients and prompting an expensive recall. The root cause? A confusing interface that made it easy to enter the wrong dosage.

Regulators like the FDA know how critical usability is. That’s why they emphasize usability engineering as part of the approval process. Designing with usability in mind isn’t just about compliance—it’s about ensuring the safety and trust of everyone who uses your device.

IEC 62366 for medical devices tackles this problem head-on. By following its guidelines, you can identify usability risks, address them before they become problems, and create a device that feels intuitive to users.

Because let’s face it: A device that’s easy to use isn’t just safer—it’s more likely to win over regulators, users, and your competition.

The IEC 62366 for Medical Devices Process: Step-by-Step Guide

Designing a medical device with usability in mind might sound overwhelming, but IEC 62366 breaks it down into a structured, step-by-step process. Let’s walk through the key phases:

1. Prepare Use Specification

The first step is to define the device’s intended use. This includes:

  • Intended medical indication: What is the device meant to treat or diagnose?
  • Intended patient population: Who will use it? Patients, healthcare providers, or both?
  • Intended part of the body or tissue: Where will the device be applied or interacted with?
  • Intended user profile: Define the users’ skills, experience, and training levels.
  • Intended use environment: Where will the device be used—home, hospital, or field settings?
  • Operating principle: How does the device work?

This stage lays the groundwork by detailing exactly what the device is for and who will interact with it.

Here, you identify potential hazards related to user interaction:

  • User interface characteristics: What features could lead to safety issues or user errors?
  • Known or foreseeable hazards: Are there any device-specific risks, based on previous models or similar devices?
  • Use errors: Pinpoint where users are most likely to make mistakes.

By identifying these risks early, you can design solutions to minimize the chances of harm.

Now, it’s time to define the scenarios where these risks could manifest. This includes:

  • Selecting hazard-related use scenarios for evaluation: These are the situations where errors could cause harm.
  • Documentation: Record the rationale behind choosing specific scenarios and the results of applying your selection scheme.

These steps help you to prioritize the risks and ensure that the most dangerous scenarios are given special attention.

4. Establish User Interface Specification

Next, define the user interface (UI) specifications. This should cover:

  • Testable technical requirements: What must the interface be capable of?
  • Accompanying documentation: What instructions or warnings need to be provided to users?
  • Training requirements: Is there any specialized training needed for the user to operate the device correctly?

These specifications guide your development team to ensure the UI meets all necessary safety and usability standards.

5. Establish User Interface Evaluation Plan

Planning is key to assessing usability. This includes:

  • Formative evaluations: Regular testing of the design during development to gather feedback and improve.
  • Summative evaluations: Final testing to ensure the design meets safety and usability criteria before launch.
  • Test environment and conditions: Document how the testing environment mirrors real-world use, including whether personal protective equipment (PPE) or specific social conditions (stress, urgency) will be part of the test.

By establishing this plan, you set the stage for thorough usability testing to validate your design.

6. Perform Formative Evaluation

Formative evaluations happen throughout the design process. This step helps to refine the design by:

  • Collecting feedback from users and making necessary adjustments.
  • Providing training, if needed, to ensure users can engage with the device properly.

This iterative process ensures continuous improvement before final validation.

7. Perform Summative Evaluation

In this phase, you evaluate the design with a final round of testing:

  • Documenting all use errors: If any errors lead to hazardous situations, address them by revisiting previous steps.
  • Evaluating whether further improvements are needed: If errors don’t present significant risks, assess whether they need further attention or if the design is ready for market.

Summative evaluations ensure that the device is both safe and functional, with no major usability concerns remaining.

IEC 62366 helps turn what feels like a daunting task into a manageable, repeatable process. By following these steps, you’re not just designing a device—you’re creating a safer, more intuitive experience for everyone who uses it.

Benefits of Following IEC 62366 for Medical Devices

So, why go through all the effort of following IEC 62366 for medical devices? Beyond meeting regulatory requirements, this standard brings a host of tangible benefits for medical device manufacturers:

  1. Improved User Satisfaction and Trust
    When a device is intuitive and easy to use, it naturally builds confidence in the user. Whether it’s a surgeon in a high-stakes operation or a patient managing their care at home, a well-designed device fosters trust and loyalty.
  2. Increased Likelihood of Regulatory Approval
    Regulatory bodies like the FDA and EU MDR place a strong emphasis on usability. Following IEC 62366 not only helps you address their requirements but also streamlines the approval process by demonstrating your commitment to safety and usability.
  3. Reduced Liability Risks
    Poor usability can lead to use errors, adverse outcomes, and even recalls—all of which can cost millions in legal fees, settlements, and lost reputation. Addressing usability risks upfront minimizes these costly risks.
  4. Competitive Advantage
    In a crowded market, usability can set your device apart. A device that’s easier to use is more likely to be adopted by healthcare providers and preferred by patients, giving you an edge over competitors.

Following IEC 62366 for medical devices isn’t just about compliance—it’s about creating medical devices that users prefer, regulators approve, and the market rewards.

Tips for Implementing IEC 62366 for Medical Devices in Your Process

Aligning your medical device development process with IEC 62366 doesn’t have to feel overwhelming. Here are practical tips to make usability engineering a natural part of your workflow:

  1. Start Early
    Usability should be a consideration from day one. Building usability into your design from the concept phase is far easier—and less costly—than trying to retrofit it later.
  2. Leverage Cross-Functional Teams
    Usability engineering isn’t a solo effort. Bring together designers, engineers, regulatory experts, and even marketing teams. Each perspective contributes to a more holistic understanding of the user experience.
  3. Document Everything
    Regulatory bodies love thorough documentation. Keep detailed records of your usability engineering activities, from identifying risks to validating your designs. This will make audits and submissions much smoother.
  4. Conduct Iterative Testing
    Don’t wait until the end to test usability. Regularly involve real users in testing prototypes. Iterative testing helps you catch and fix problems early, ensuring your final design meets user needs.
  5. Stay Open to Feedback
    Usability doesn’t end at launch. Collect user feedback post-market and use it to make improvements. This proactive approach helps you maintain compliance and keeps your device user-friendly over time.

Implementing IEC 62366 is as much about mindset as it is about process. By focusing on the user experience at every stage, you’re setting your device—and your company—up for success.

IEC 62366 for Medical Devices and the Culture of Usability

Usability is a mindset that can transform your organization. IEC 62366 for medical devices encourages manufacturers to embrace a culture of usability, aligning with broader goals of quality and compliance.

  1. Quality Beyond Compliance
    A culture of usability goes hand-in-hand with a quality-focused organization. When usability is prioritized, it naturally leads to better-designed devices that meet and exceed regulatory expectations.
  2. User-Centered Thinking
    Building a culture of usability means putting users at the heart of your process. This isn’t just about meeting standards—it’s about genuinely understanding the challenges users face and designing solutions that fit seamlessly into their lives.
  3. Cross-Functional Alignment
    A usability-focused culture isn’t confined to one team. It requires collaboration across departments, from R&D to regulatory to marketing. This alignment ensures usability isn’t an afterthought but a guiding principle throughout the product lifecycle.
  4. Sustainable Innovation
    Fostering usability as a core value positions your company for long-term success. Devices that are intuitive and effective are more likely to be adopted, trusted, and recommended, paving the way for sustained growth and innovation.

Embracing IEC 62366 for medical devices is about more than compliance—it’s about creating a workplace where usability and quality drive every decision. When usability becomes second nature, the results speak for themselves: safer devices, happier users, and a stronger reputation.

Bringing Usability to the Forefront with IEC 62366 for Medical Devices

Designing for usability isn’t just a nice-to-have—it’s a must-have in today’s medical device landscape. IEC 62366 for medical devices provides the blueprint to create devices that are safe, effective, and intuitive, setting your products up for success in the real world.

By integrating usability engineering into your process, you’re not only meeting regulatory requirements but also delivering on a promise to your users: that their safety, experience, and satisfaction are your top priorities.

At Fission Consulting, we understand how complex this process can feel. From interpreting IEC 62366 requirements to implementing usability practices across your team, we’re here to help. With our expertise, you can confidently align your device design with usability standards—and bring products to market that stand out for all the right reasons. Ready to take the next step? Let’s connect and discuss how we can help your team design with usability in mind.

FAQ

What is IEC 62366 for medical devices?

IEC 62366 is the international standard that guides manufacturers in designing medical devices with usability in mind. It focuses on minimizing risks caused by user errors, ensuring devices are safe and effective.

Why is IEC 62366 important for medical devices?

IEC 62366 helps manufacturers reduce usability-related risks, improve patient safety, and meet regulatory requirements like FDA and EU MDR. It’s a critical tool for creating intuitive and reliable devices.

How does IEC 62366 for medical devices impact regulatory approval?

Following IEC 62366 ensures your device meets usability engineering standards required by regulatory bodies. It demonstrates a commitment to safety and effectiveness, making approval processes smoother.

What are the key steps in the IEC 62366 usability engineering process?

The process includes defining intended use, identifying usability risks, designing to mitigate risks, and validating usability. These steps ensure the device is user-friendly and safe in real-world scenarios.

How can I implement IEC 62366 for medical devices in my development process?

Start usability engineering early, involve cross-functional teams, document activities thoroughly, and conduct iterative testing with real users. Partnering with experts like Fission Consulting can streamline the process.

Written By Jeremy Moore

Related Posts

Join the Newsletter

Get the best of our blog content delivered straight to your inbox.

    We won't send you spam. Unsubscribe at any time.

    0 Comments

    Submit a Comment

    Your email address will not be published. Required fields are marked *